Notices:

Hotline: 86-20-32290092

AE Sensor

您现在的位置是: 首页 > PRODUCTS > AE Sensor

    Guide Line for AE Sensor Selection

    Brief instruction of sensors:

    Sensor models are complete for customers’ different needs, so as to meet different application demands of acoustic emission detection.

    In terms of acoustic emission position, most actual application is in the stable metallic structure, for example: pressure vessels. The anisotropy of this material is relatively small, as well as the attenuation coefficient of acoustic wave, frequency band range is between 25KHz~750KHz.It is suitable to choose resonant sensors.

    Resonant narrow-band sensors are widely used for testing acoustic emission signals in engineering materials, which are under the condition of metallic material application and other using conditions.

    Resonant narrow-band sensors have high sensitivity and SNR, which are cheap, and have different specifications. On the occasion of knowing the basic characteristics of sound source propagation, if customer who want to process or enhance the systematic sensitivity once acquired the sound signals within a range of frequencies, it is better to choose appropriate resonant sensors, for example, sound localization. 

    It should be pointed out that the so-called resonant narrow-band sensor is not only sensitive to a certain frequency signal, but to a certain frequency band, once to the other frequency band, the signal sensitivity is low.


    声发射探头定制


    Model (New)Model (Old)Resonant frequency Frequency rangeSensitivity peakBuilt-in Pre-amplifierApplicable temperateureSize mmCase materialFace materialProtection GradeConnector Connector LocationN.W.(G,1pcs)Signal Cable modelMangetic Holder Size(mm)Holder Model
    W800/1CG80800KHz50KHz~800KHz>65dB/-20~80℃Φ19×15SUS-304ceramicIP68BNCopposite side of the cable44RG17813M20
    W800SR800600KHz50KHz~800KHz>65dB/-20~80℃Φ19×15SUS-304ceramicIP62M5Side22RG17813M20
    W500/1CG50500KHz100-1000kHz>65dB/-20~120℃Φ19×15SUS-304ceramicIP68BNCopposite side of the cable22RG17813M20
    WM500/1MG50500KHz100-1000kHz>65dB/-20~50℃Φ4.7×4.0SUS-304ceramicIP68BNCopposite side of the cable25RF-1.13--
    W500WG50500KHz100-1000kHz>65dB/-20~120℃Φ19×15SUS-304ceramicIP62M5Side17RG17813M20
    G150SR150M150KHz60KHz~400KHz﹥75dB/-20~120℃Φ19×15SUS-304ceramicIP62M5Side22RG17813M20
    G150/1CG15150KHz60KHz~400KHz﹥75dB/-20~120℃Φ19×15SUS-304ceramicIP68BNCopposite side of the cable44RG17813M20
    GIS150LS150 5VDC150KHz60KHz~400KHz>65dB26dB5V-20~50℃Φ22×25.5SUS-304ceramicIP62SMASide177STYV-50-220Waiting to be named
    GI150/2LG15150KHz60KHz~400KHz>65dB26dB5V-20~50℃Φ22×25.5SUS-304ceramicIP62SMASide44STYV-50-220Waiting to be named
    GI150/1PG15150KHz60KHz~400KHz﹥115dB40dB28V-20~50℃Φ22×25.5SUS-304ceramicIP62SMASide198STYV-50-220Waiting to be named
    GI150SRI150150KHz60KHz~400KHz﹥115dB40dB28V-20~50℃Φ30×36.5SUS-304ceramicIP62BNCSide120SYV-50-335M36B
    G150/2XG15150KHz60KHz~400KHz>70dB/-20~120℃Φ19×19.5SUS-304SUS-304IP68BNCopposite side of the cable55RG17817H20
    GH150HG15c150KHz60~400KHz>63dB/-20~600℃Φ19×19.5Stainless invarStainless steel invarIP68BNCopposite side of the cable198RG17817High temperature Magnetic Holder
    GD150DG15150KHz60~400KHz﹥65dB/-20-120℃Φ19×19.5SUS-304ceramicIP68dual-core BNCopposite side of the cable33RVVP-317H20
    GM150SR150S150kHz70kHz-280kHz>68dB/-20~120℃Φ7.8×19SUS-304ceramicIP62M5Top4RG17817M20A
    G80G880KHz20KHz~180KHz﹥70dB/-20~80℃Φ19×19.5SUS-304ceramicIP62M5Side33RG17817H20
    GI40/2BF4050KHz15KHz~70KHz﹥115dB40dB28V-20~50℃Φ41×92SUS-304SUS-304IP68BNCOpposite side of the cable710SYV-50-3--
    GI40SRI4050KHz15KHz~70KHz﹥115dB40dB28V-20~50℃Φ30×57SUS-304ceramicIP62BNCSide192SYV-50-355M36A
    G40SR40M40KHz15KHz~70KHz﹥75dB/-20~120℃Φ22×36.8SUS-304ceramicIP62M5Side88RG17835M36
    GIS35LS35 5VDC35KHz15KHz~70KHz>65dB26dB5V-20~50℃Φ22×36.8SUS-304ceramicIP62SMASide60STYV-50-235Waiting to be named
    GI35/1LG335KHz15KHz~70KHz>65dB26dB5V-20~50℃Φ22×36.8SUS-304ceramicIP62SMASide60STYV-50-235Waiting to be named
    GI35PG335KHz15KHz~70KHz﹥115dB40dB28V-20~50℃Φ22×36.8SUS-304ceramicIP62SMASide58STYV-50-235Waiting to be named
    GD40DG435KHz15KHz~70KHz>65dB/-20-120℃Φ22×25SUS-304ceramicIP68lemo Multi Coreopposite side of the cable115RVVP-321M36
    G10SR10B/1Hz-15kHz>80dB/-20-120℃Φ31×38SUS-304ceramicIP62BNCSide210SYV-50-335M36B
    G10/1SR10C/1Hz-15kHz>80dB/-20-120℃Φ31×38SUS-304ceramicIP62lemo Single CoreSide220SYV-50-335M36B
    GI10BE10/1Hz-15kHz﹥115dB26dB5V-20~50℃Φ38.5×85SUS-304SUS-304IP68BNCOpposite side of the cable360SYV-50-3-With magnetic suction


    Download table of modle selection guide 

     


    Main characteristics:


    1.The models of the AE sensors are complete, cover application of various frequency band, temperature, size; 

    2.High sensitivity, good consistency, each sensor has been strictly tested before delivery

    3.Can be used under high temperature which achieves 600 degrees centigrade, sensitivity differences between high and normal temperature are small.

    4.Have special purpose modes which obtain built-in magnetic clamp、water proof and so on;

    5.The design engineers can design and make special sensors according to user’s demand at any time。

     
    Extended Reading:

    Secondary calibration of the AE sensors;

    Application methods of Acoustic sensors 、pre-amplifier

    Brief introduction of calibration system from Qingcheng AE Institute(Guangzhou)


    Brief introduction of acoustic emission sensor calibration system of QingCheng AE Institute(GuangZhou) Co.,ltd